Series 8434 Analog 4 ... 20 mA Output pen size light meter 


8 4 3 4 X                
    Spectral Range
    6 = all UV
  7 = UVA (figure 1)
    8 = UVB (figure 2)
    9 = UVC (figure 3)
     

 

     
3D AutoCAD drawing of sensor (zipped)   -   DWG = [R13] [R14] [R2000]       DXF = [R13] [R14] [R2000]

Technical Data Description
Operating temp: - 20 ...+   60 degree C The light meter measures intensity of light in a certain spectral range (see above).  A Silicon Photodiode is used as a detector that provides 5% linearity.  The output produced is a 4 ... 20 mA current loop.  The unit does not come calibrated, although it may be calibrated upon request.  The sensor is mounted using the cylindrical part of the surface.  

 

- 04 ...+ 140 degree F
Weight:    6 oz (0.17 kg)
Protection: IP 54, NEMA 3
Housing: Stainless Steel
Humidity: Up to 98% permissible
Linearity: 5%
Cone Angle:  30 degrees Typical Output is shown on the graph.
Light Sensitivity Diagrams
  Figure 1 (UVA)
  Figure 2 (UVB)
  Figure 3 (UVC)
Dimensions
For a nominal charge of $100.00, Hohner Corp. will test and evaluate your samples to ensure this product meets your specific requirements and standards.  Should modifications be required, Hohner Corp. will advise in writing of any additional charges.  