Series 4633 OEM Devicenet roughness sensor 



4 6 3 3                  
   
   
Scientific term: Scatterometer
 

Used for Texture, imperfections, uniformity, seam and crack, glossiness and porosity

Buy online at Thomas Register
3D AutoCAD drawing of sensor (zipped)   -   DWG = [R13] [R14] [R2000]       DXF = [R13] [R14] [R2000]

Technical Data Description
Operating temp: - 20 ...+   60 degree C The roughness sensor has a built in infrared light source.  Scattered light reflected from a rough surface is analyzed and the roughness factor is calculated in absolute or relative units. Some applications may need calibration.  Due to the sensitivity and high sample rates it is advised that the surface sensor be mounted firmly avoiding any environmental light.  The roughness sensor is a one dimensional instrument.  Circular movement over the probe changes measurement results.
- 04 ...+ 140 degree F
DeviceNet powered, 6ft drop cable
Current consumption: 50 mA (max.)
Weight:    6 oz (0.17 kg)
Protection: IP 55, NEMA 3
Housing: ABS chromed
Humidity: Up to 98% permissible
Roughness Range: 0.05 ... 20 microns
Analyzed surface 
area: 10mm2
Illumination: 890 nm
Technical Description
To obtain the relative roughness size R, customer must apply the next formula:
Sr - intensity of reflected component    
Ss - intensity of the scattered component
k scaling coefficient
The scaling coefficient k can be any number. To provide the optimum range-resolution relation, for machined surfaces k is recommended to be 100.
DeviceNet Roughness Sensor returns 4 bytes of data scheduled as following:
Device Configuration EDS
ODVA profile: Resolver Vendor ID 34
Explicit Peer to Peer Messaging Not supported Devicetype  9
I / O Peer to Peer Messaging Not supported Product code 5
Configuration consistency value Not supported Product name MTDR
Faulted node recovery Not supported Catalog 10 bit roughness sensor
Baud rate Supported Expected response data 4 bytes
Master / Scanner Not supported Maximum value 10 bit
I / O Slave messaging Not supported
Bit strobe Not supported Standards
Poll  Supported Tested by University of Michigan
Cyclic Not supported European standard EN 50324
Change of state Not supported Certified to IP54
Dimensions
For a nominal charge of $100.00, Hohner Corp. will test and evaluate your samples to ensure this product meets your specific requirements and standards.  Should modifications be required, Hohner Corp. will advise in writing of any additional charges.

Cleaning of Device: Should be done regularly with a clean, dry, lint free cotton cloth.

The Life expectance of this device is 50,000 hours

Two 1/4" holes 2-3/4" apart are fro precision mounting with dowel pins.

 