Series 2634 OEM roughness detector with 4 ... 20 mA Analog Ouptut |
|
|
2 | 6 | 3 | 4 | ||||||||||||||||||||||
|
|
||||||||||||||||||||||||||
| Surface area is 10 mm2 | ||||||||||||||||||||||||||
| Distance to target is 1/8" | ||||||||||||||||||||||||||
| 3D AutoCAD drawing of sensor (zipped) - DWG = [R13] [R14] [R2000] DXF = [R13] [R14] [R2000] | ||||||||||||||||||||||||||
| Technical Data | Description | |||
| Operating temp: | - 20 ...+ 60 degree C | The
roughness sensor has a built in infrared light
source. Scattered
light reflected from a rough
surface is analyzed and the roughness factor is calculated in the
following way:
|
||
| - 04 ...+ 140 degree F | ||||
| Weight: | 6 oz (0.17 kg) | |||
| Protection: | IP 54, NEMA 3 | |||
| Housing: | Aluminum | |||
| Humidity: | Up to 98% permissible | Output | ||
| Roughness range: | 0.05 to 20 micron | A Sample output is shown below | ||
| Illumination: | 890 nm | |||
|
||||
| Connections | ||||
| 5 pole mini | ||||
| 1 | + 5 to 24 Volts | |||
| 2 | GND | |||
| 3 | Output | |||
| 4 | NC | |||
| 5 | NC | |||
| Dimensions |
![]() |
For a
nominal charge of $100.00, Hohner Corp. will test and evaluate your
samples to ensure this product meets your specific requirements and
standards. Should modifications be required, Hohner Corp. will
advise in writing of any additional charges.
Cleaning of Device: Should be done regularly with a clean, dry, lint free cotton cloth. The Life expectance of this device is 50,000 hours
|
| 1 800 295 5693 |
UK + 44 01978 363 888 |
BR 55 01938 775214 |