Series 5760 OEM material detector |
|
"Teachable" Detector Based on True False Principal |
|
|
5 | 7 | 6 | 0 | ||||||||||||||||||||||
|
Options: |
1 mm2 surface detection area | |||||||||||||||||||||||||
| Line detecting for large surfaces | ||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||
| 3D AutoCAD drawing of sensor (zipped) - DWG = [R13] [R14] [R2000] DXF = [R13] [R14] [R2000] | ||||||||||||||||||||||||||
| Technical Data | Connections | ||
| Operating temp: | - 20 ...+ 60 degree C | 4 pole square connector | |
| - 04 ...+ 140 degree F | GND = GND | ||
| Weight: | 6 oz (0.17 kg) | 1 = Power Supply +11 ... 24 Volts, 100 mA consumption | |
| Protection: | IP 54, NEMA 3 | 2 = Push Pull output, High / Low, max 50 mA | |
| 3 = Push Pull output, High in tolerance field, max 50 mA | |||
| Housing: | Die Cast Zinc Alloy | ||
| Humidity: | Up to 98% permissible | ![]() |
|
| Spectral Range: | 620 ... 680 nm | ||
| Capture time: | 30 msec | ||
| Data capture: | 6 x 10 bit | ||
| Description | |||
| The
polarimeter analyzes the polarization state of light. Application software
shows degree-of-polarization, azimuth angle, ellipticity, normalized
Stokes vector and Jones vector. Device’s coordinate frame is shown in
the instruction file. Input aperture has a diameter of 3mm. Due to
sensitivity it is recommended that the polarimeter be mounted firmly and
light under analysis must fall straight in to the device. If it is
possible, speckles in light should be avoided. If the device is included
in an ellipsometer, it calculates surface’s complex refractive index.
First, the detector is placed over a master sample and the button is pressed and held for three seconds. The data is then stored or "taught" to the device. Second, immediately after the data has been stored, depress the same button again in short presses to set the tolerance. Each press is equivalent to 0.2% tolerance. The maximum tolerance is 3.2%. There are 20 seconds to "calibrate" the detector. Example: To set the detector to sense a a certain polarization state from a master with a 1.2% tolerance. The detector is placed on the sheet and the button is pressed for 3 seconds and released, then the button is pressed in short increments 6 times. (6 x 0.2 = 1.2) |
|||
| Output | |
![]() |
Sample of Output |
| Part 1: Low out of Tolerance | |
| Part 2: Low in Tolerance | |
| Part 3: Hi in Tolerance | |
| Part 4: Part 4: Hi out of Tolerance | |
| Dimensions | |
![]() |
For a
nominal charge of $100.00, Hohner Corp. will test and evaluate your
samples to ensure this product meets your specific requirements and
standards. Should modifications be required, Hohner Corp. will
advise in writing of any additional charges.
Cleaning of Device: Should be done regularly with a clean, dry, lint free cotton cloth. The Life expectance of this device is 100,000 hours |