Series 4534 OEM Flaw Meter with 4...20 mA analog output


4 5 3 4                  
   
 
 
 
 

Common Term: line scanner

Buy online at Thomas Register  
3D AutoCAD drawing of sensor (zipped)   -   DWG = [R13] [R14] [R2000]       DXF = [R13] [R14] [R2000]

Technical Data Description
Operating temp: - 20 ...+   60 degree C The Flaw meter is adjustable to lengths in range of 12... 500 mm.  Customer must adjust the lens to the required working distance.  The device can compare gray scales in 128 sections from a surface under analysis.  The linear PDA has 128 pixels.  The common term for the flaw sensor is the "line scanner". Lens placed in front of a linear detector projects on it the intensity distribution from a part being inspected. By reading the condition of pixels customer can detect surface flaws or measure dimensions. Sensor can be scanned as fact as 2 MHz, and it must be mounted firmly against parts to inspect. Analog output 4...20mA provided to PLC can be digitized or use directly for analog circuits.
- 04 ...+ 140 degree F
Weight:    6 oz (0.17 kg)
Protection: IP 54, NEMA 2
6ft cable
Housing: ABS chromed
Humidity: Up to 98% permissible
Application Examples
Flaw Sensor can be used for the two following purposes: 
- on-line dimensional measurements
- on-line surface inspection for flaws (cracks, imperfections, etc.)
(See the pictures below)

Dimensions
For a nominal charge of $100.00, Hohner Corp. will test and evaluate your samples to ensure this product meets your specific requirements and standards.  Should modifications be required, Hohner Corp. will advise in writing of any additional charges.

Cleaning of Device: Should be done regularly with a clean, dry, lint free cotton cloth.

The Life expectance of this device is 50,000 hours

Two 1/4" holes 2-3/4" apart are for precision mounting with dowel pins.


1 800 295 5693 

UK   + 44 01978 363 888

BR   55 01938 775214