Series 5460 OEM color meter 


 "Teachable" Detector Based on True False Principal


5 4 6 0                  
   
 

Options:  

1 mm2 surface detection area
    Line detecting for large surfaces
   
 
 
 
   
3D AutoCAD drawing of sensor (zipped)   -   DWG = [R13] [R14] [R2000]       DXF = [R13] [R14] [R2000]

Technical Data Connections
Operating temp: - 20 ...+   60 degree C 4 pole square connector
- 04 ...+ 140 degree F GND = GND
Weight:    6 oz (0.17 kg) 1 = Power Supply +11 ... 24 Volts, 100 mA consumption
Protection: IP 54, NEMA 3 2 = Push Pull output, High / Low, max 50 mA
3 = Push Pull output, High in tolerance field, max 50 mA
Housing: Die Cast Zinc Alloy
Humidity: Up to 98% permissible
Capture time:  10 m sec
Data capture:  3 x 10 bit
Input aperture:  Diffuser 5mm dia 
Description
The Colour Sensor measures colour reflection coefficients of surfaces.  It has a built in halogen light source.    Spectral sensitivities are as follows:
Spectral range 420 .. 700 nm
Spectral response
Red - 420..530 nm
Green - 490-600 nm
Blue - 590-700 nm
Number of elements in the detector: 3
Signal from each channel is processed by a 10-bit analog-to-digital converter.  2 high-low opto-coupled outputs can be activated

First, the detector is placed over a master sample and the button is pressed and held for three seconds.  The data is then stored or "taught" to the device.  Second, immediately  after the data has been stored, depress the same button again in short presses to set the tolerance.  Each press is equivalent to 0.2% tolerance.  The maximum tolerance is 3.2%.  There are 20 seconds to "calibrate" the detector.

Example:  To set the detector to sense a sheet of paper with a certain red from the master with a 1.2% tolerance.  The detector is placed on the sheet and the button is pressed for 3 seconds and released, then the button is pressed in short increments 6 times. (6 x 0.2 = 1.2)

Output
Sample of Output
Part 1: Part 1: Low out of Tolerance
Part 2: Part 2: Low in Tolerance
Part 3: Part 3: Hi in Tolerance
Part 4: Part 4: Hi out of Tolerance
Dimensions
For a nominal charge of $100.00, Hohner Corp. will test and evaluate your samples to ensure this product meets your specific requirements and standards.  Should modifications be required, Hohner Corp. will advise in writing of any additional charges.

Cleaning of Device: Should be done regularly with a clean, dry, lint free cotton cloth.

The Life expectance of this device is 100,000 hours


1 800 295 5693 

UK   + 44 01978 363 888

BR   55 01938 775214